430,000 FortiGate Devices Exposed in FortiBleed Ransomware Link|Adobe fixed multiple maximum-severity flaws in ColdFusion and Campaign Classic|Alleged Scattered Spider Hacker Extradited to U.S. to Face Cybercrime Charges|Oracle E-Business Suite Flaw Under Active Attack, 950 Systems Exposed|Azure CLI Targeted in LSHIY Password Spray Campaign Across 64 Orgs|CISA Warns BlueHammer Flaw Is Now Exploited in Ransomware Attacks|RustDuck: The Botnet That’s Still Small but Engineering Like It Plans to Grow|GuardFall Flaw Hits 10 of 11 Popular Open-Source AI Agents|XSS.is, The Forum That Ran the Ransomware Supply Chain Is Down. The Market Isn’t|U.S. CISA adds SimpleHelp flaw to its Known Exploited Vulnerabilities catalog|Hackers Steal Data of 4.38 Million Aflac Japan Customers|Apple Fixes WebKit Flaws in iOS and macOS, With Help From AI Tools|430,000 FortiGate Devices Exposed in FortiBleed Ransomware Link|Adobe fixed multiple maximum-severity flaws in ColdFusion and Campaign Classic|Alleged Scattered Spider Hacker Extradited to U.S. to Face Cybercrime Charges|Oracle E-Business Suite Flaw Under Active Attack, 950 Systems Exposed|Azure CLI Targeted in LSHIY Password Spray Campaign Across 64 Orgs|CISA Warns BlueHammer Flaw Is Now Exploited in Ransomware Attacks|RustDuck: The Botnet That’s Still Small but Engineering Like It Plans to Grow|GuardFall Flaw Hits 10 of 11 Popular Open-Source AI Agents|XSS.is, The Forum That Ran the Ransomware Supply Chain Is Down. The Market Isn’t|U.S. CISA adds SimpleHelp flaw to its Known Exploited Vulnerabilities catalog|Hackers Steal Data of 4.38 Million Aflac Japan Customers|Apple Fixes WebKit Flaws in iOS and macOS, With Help From AI Tools|
Advertisement

Ad Placeholder

Full Width × 90

Breaking News

Schneider Electric Development Tools InduSoft Web Studio and InTouch Machine Edition are affected by a critical buffer flaw

Researchers at Tenable have disclosed technical details and a PoC code for a critical remote code execution vulnerability affecting Schneider Electric InduSoft Web Studio and InTouch Machine Edition products. Experts at security firm Tenable have discovered a critical remote code execution vulnerability affecting Schneider Electric InduSoft Web Studio and InTouch Machine Edition products. The InduSoft Web Studio […]

Schneider Electric InduSoft Web Studio

Researchers at Tenable have disclosed technical details and a PoC code for a critical remote code execution vulnerability affecting Schneider Electric InduSoft Web Studio and InTouch Machine Edition products.

Experts at security firm Tenable have discovered a critical remote code execution vulnerability affecting Schneider Electric InduSoft Web Studio and InTouch Machine Edition products.

The InduSoft Web Studio is a development tool for human-machine interfaces (HMIs), supervisory control and data acquisition (SCADA) systems and embedded instrumentation solutions, while the InTouch Machine Edition is an HMI/SCADA development tool.

Boot products are widely adopted in almost any industry, from energy to building automation.

Researchers at Tenable discovered a stack-based buffer overflow vulnerability in the tools that can be exploited by a remote unauthenticated attacker to trigger a DoS condition or to execute arbitrary code execution with elevated privileges.

Tenable disclosed technical details and the following proof-of-concept (PoC) code for the vulnerability:

cat <(echo -ne '\x02\x57\x03\x02\x32'`python -c 'print "A"*0x500'`'\x09\x0a\x03') - | nc <target_host> 1234

Schneider Electric InduSoft Web Studio

According to the researchers, the buffer overflow issue could be exploited to fully compromise the vulnerable system and use it as an entry point in the target network.

An attacker can exploit the flaw by sending specially crafted packets and use HMI clients to read and write tags, and monitor alarms and events, he only needs to remotely connect to port 1234 on the targeted machine.

“Tenable Research found a new stack-based buffer overflow in InduSoft Web Studio and InTouch Machine Edition. A threat actor could send a crafted packet to exploit the buffer overflow vulnerability using a tag, alarm, event, read or write action to execute code.” reads the analysis published by Tenable.

“The vulnerability can be remotely exploited without authentication and targets the IWS Runtime Data Server service, by default on TCP port 1234. The software implements a custom protocol that uses various “commands.” This vulnerability is triggered through command 50, and is caused by the incorrect usage of a string conversion function.”

The flaw affects InduSoft Web Studio v8.1 and prior, and InTouch Machine Edition 2017 v8.1 and prior.

Schneider Electric addressed the vulnerability with the release of v8.1 SP1 for both products, security patches were made available on April 6.

“Customers using InduSoft Web Studio v8.1 or prior versions are affected and should upgrade and apply InduSoft Web Studio v8.1 SP1 as soon as possible.” reads the advisory published by Schneider Electric.

“Customers using InTouch Machine Edition 2017 v8.1 or prior versions are affected and should upgrade and apply InTouch Machine Edition 2017 v8.1 SP1 as soon as possible.”